Need Appliance Repair Service? Have a general question?
We love solving problems! Let us know how we can help by reaching out below.
Local Reviews
for Indian Rocks Beach, FL
Carol
Carol - Indian Rocks Beach, FL
He told me the knocking sound in my refrigerator is normal and there is nothing we can do about it
Yondi
Youlonda - Indian Rocks Beach, FL
Tech was amazing...professional and super pleasant. Not thrilled w/the office, but the tech made up for their short comings
Great service
Gary - Indian Rocks Beach, FL
Great service
Fast service
Randy - Indian Rocks Beach, FL
Technician was extremely knowledgeable and worked quickly.
Professional & competent
Peter - Indian Rocks Beach, FL
Tom was very helpful, courteous and knowledgeable about his work.

Jospeh G.
REFRIGERATOR IKEA ISC21CNEDS00 Q1=NO Q2=NO---replaced the bad diffuser/damper. Tested and fridge is cooling and unit if functioning as designed. Due to COVID-19 protocol did not get signature.

Jospeh G.
MICROWAVE JENN-AIR JMW3430DS02 Q1=NO Q2=NO---extra labor=Chris-JQSR300AL2===Customer agreed with Waiver. Replaced UI console. tested and unit is functioning as designed. Due to COVID-19 protocol did not get signature

James B.
REFRIGERATOR IKEA ISC21CNEDS00 SR#7728054942q1 no q2 nono sign covid 19I documented knocking with tech line. Normal sound on fridge it is refrigerant coming out of evap at high pressure.

Jospeh G.
MICROWAVE JENN-AIR JMW3430DS02 JQJSFQJAPL1.3 ===Customer is having problems connecting with the wifi also the lights turn on by them selves. Checked and unit does not have correct verison. Ordering new UI Console.; ordrng 1 W11236885 (ui console) and 1 ovendolly (ovendolly) and 1 W10821712 (control)

Jospeh G.
REFRIGERATOR JENN-AIR JS42SSDUDE00 Q1=NO Q2=NO---Found the stoped on the bottom right (Fridge door) bottom hinge to have come off(Unscrew). Was able to put the stopped plate on and secure the screw to stop the fridge door from swinging open. Also found the freezer gasket to not be sealing correctly. Applied heat to the gasket to fix. Unit is functioning as designed. Due to COVID-19 protocol did not get signature.

Tom P.
REFRIGERATOR WHIRLPOOL WRX735SDHZ02 installed new fill tube and IM - tests goodq1 no q2 no

James B.
REFRIGERATOR MAYTAG MFI2570FEZ02 q1 no q2 nono sign covid 19I redid the tube water line- old one defective. - same parts as last 1 year warranty

James B.
REFRIGERATOR WHIRLPOOL WRS321SDHV01 freezer and fresh food sensors are good. I checked temps in the fridge and found unti is 37 degrees in the fridge and -1 in the freezer. I told customer these are normal temps inside the fridge. This model can freeze items in the top shelf or lower suger content items. I told customer where to place those items so its not an issue.

James B.
REFRIGERATOR WHIRLPOOL WRS321SDHV01 freezer and fresh food sensors are good. I checked temps in the fridge and found unti is 37 degrees in the fridge and -1 in the freezer. I told customer these are normal temps inside the fridge. This model can freeze items in the top shelf or lower suger content items. I told customer where to place those items so its not an issue.

Tom P.
KITCHEN JENN-AIR JDB9000CWS3 installed new upper adjuster/tack assembly - tests good

James B.
REFRIGERATOR WHIRLPOOL WRF560SEHZ00 I found fridge is -2 in the freezer and 40 in the fridge which is normal temps. Customer said sometimes getting a rattle. I found the noise is damper door opening and closing which is normal sound.

James B.
FREEZER WHIRLPOOL KUDF204ESB I found ice on bottom of slide out drawer on the drawer itself. I took heat gun to the gasket and instructed customer on making sure door is fully closed.

James B.
DISHWASHER AMANA ADB1400AGW1 SR#7727282039I gave customer extra hose orginal was not sealing proper. Customer had dishwasher in different unit which was unit 7. In unit 11 the unit was draining just fine.

James B.
MICROWAVE WHIRLPOOL WMH31017HB2 I found unit is heating and found no issues. Microwave started everytime and property manager here also confirming .

Tom P.
REFRIGERATOR WHIRLPOOL WRS321SDHV01 installed new water filter housing and filter aswell as new damper assemby too - tests good

James B.
REFRIGERATOR WHIRLPOOL WRX735SDHZ02 I found there was no water coming out of the dispenser. I pulled fridge out and turned up the water to the fridge. Unit now has water.

James B.
REFRIGERATOR WHIRLPOOL WRS325FDAM01 Customer refuses to pay for repaiir Unit will need new led lights in the fridge. They went out. I gave estimate to customer for repair .

Tom P.
ICEMAKER KITCHENAID KUIX305ESS1 "unit making loud gurggling noise, found power cord cut off and hardwires power cord to drain pump cord and pump keeping running and running, will need to replace power cord and drain pump"

Tom P.
DRYER MAYTAG MED6630HW0 "found unit running but not heating found 120vac L1 and 120vac L2 ad 0vac across L1/L2, door was also flipped by delivery installers, advising customer to call and electrician to correct power issue"

Tom P.
REFRIGERATOR WHIRLPOOL WRF560SEYM05 "defrosted freezer and replaced thermistor with foil tape and zip tie, set unit to 3/3 on temps with humidty control on - tests good"

Tom P.
N/A N/A WRF560SEYM05 "found unit freezing over and evap fan not running or entering defrost properly, ordering fan/sensor/control; ordrng 1 WPW10464673 (evap fan) and 1 WPW10383615 (thermistor) and 1 W11035836 (control)"

Tom P.
REFRIGERATOR WHIRLPOOL WRV986FDEM01 "unit not cooling in freezer section and not making ice in either compartments fridge/freezer, found unit corroding on filter drier and lekaing on to flooring rusting color, appears to be restricted in direr; ordrng 1 WPW10143759 (drier) and 1 sstech (ss tech)"

Tom P.
REFRIGERATOR MAYTAG MFX2876DRM02 installed new icemaker and turned on all fans and heaters - tests good

Kevin H.
FREEZER KITCHENAID KRFC300ESS01 Mamba Auth#KL7IT00APL1Found unit to have moisture control turned off. Advised customer to leave this turned on.

Kevin H.
REFRIGERATOR WHIRLPOOL KBFN502EPA02 Replaced defective odules and test unit tests - good.

Kevin H.
REFRIGERATOR WHIRLPOOL WRT311FZDW01 Butch ref#7725263853 Called t/l thaey advised they are putting up for review.

James B.
WASHER MAYTAG MHW5630HW0 I changed the freezer setting to allow more air in and changed the settings on the fridge to a colder setting. 0 degree freezer 50 fridge. I told customer to give unit 24 hours.

James B.
WASHER MAYTAG MHW5630HW0 I changed the freezer setting to allow more air in and changed the settings on the fridge to a colder setting. 0 degree freezer 50 fridge. I told customer to give unit 24 hours.

Kevin H.
REFRIGERATOR WHIRLPOOL KBFN502EPA02 Still need freezer lights per denis at t/l they are in sameseries as upper ff lights.; ordrng 2 W10908166 (module)s

James B.
REFRIGERATOR WHIRLPOOL WRT311FZDW01 Unit has a restriction tons of refrigerant in high side- no refrigerant coming out of low side. Needs new evap and filter drier.; ordrng 1 W10843121 (drier) and 1 W10836706 (evap)

Kevin H.
REFRIGERATOR WHIRLPOOL WRT311FZDW01 Found new compressor locked need to order and replace.; ordrng 1 WPW10507886 (Compressor)

James B.
WASHER-TOP LOAD KITCHENAID WTW5000DW1 "SR#7725068006I called whirlpool and performed tests on unit and found no error codes and all component working at time of visit. I found drain line was not at 39 inches tall which could cause issues with machine.; (created new UIS, deleted prior attachment to UisID 7425)"

Tom P.
DISHWASHER KITCHENAID KDFE104DWH0 installed new main control and found unit now powering on and filling/washing/draining proeprly - tests good

James B.
REFRIGERATOR WHIRLPOOL WRS325SDHZ02 I replaced the housing and now filter will come out.

James B.
REFRIGERATOR WHIRLPOOL WRS325SDHZ02 needs new filter housing - filter isnt popping out; ordrng 1 W11162042 (housing)

Kevin H.
REFRIGERATOR WHIRLPOOL WRT311FZDW01 Replaced defective evaporator and compressor with a new filter drier and charged with 4.24oz 134a refrigerent and test unit tests - good with good pressures and cooling normally.

Kevin H.
REFRIGERATOR WHIRLPOOL WRT311FZDW01 Replaced restricted filter drier evacuated system and held good vacuum. Recharged unit with 4.24 oz 134a refrigerent and test pressures are reading good and system is cooling.

Kevin H.
REFRIGERATOR WHIRLPOOL WRT311FZDW01 Found unit to have a restricted drier need to order and repalce.; ordrng 1 W10843121 (Drier)

Kevin H.
REFRIGERATOR WHIRLPOOL WRS321SDHZ01 Found unit to have evaporator fan motor bound in wiring removed obstruction and tied wires back and test unit tests - good. This is an empty vacation rental no signature available.

James B.
REFRIGERATOR WHIRLPOOL GSF26C5EXW00 computer not excepting credit card - called penny for payment entry 98. I ran diagnostic testing unit and it passed all the tests. I found the temp to be -5 in the freezer and 37 in the fridge is normal. Unit was empty when tenant first came in and filled product after arrival. Unit needs to be 3/4 full to cool properly.